Home > Products > Gas analyzer
Oxygen analyzer for wave soldering and reflow soldering

Oxygen analyzer for wave soldering and reflow soldering

    Oxygen analyzer for wave soldering and reflow soldering can be widely applied in the online oxygen analysis in protection gas from Wave-soldering machine, reflow-soldering machine, electron,welding furnace for semiconductor industry and sintering furnace for inactive gas, etc.

Oxygen analyzer has friendly communication menu which makes the operation visual and simple. It could keep working in the air for a long time without affecting the sensor life. The response speed is rapid and the lowest measurable unit is 0.1ppm. Power being supplied at a wide range makes it more suitable for different occasions.

Oxygen analyzer main features:

1.The imported zirconium dioxide sensor is with high measurement accuracy, a rapid response speed and long calibration cycle for features;

2.Only one random point needs to be calibrated among the whole measured range, making the calibration operation simple and convenient;

3.Function of built-in compensation system for temperature could reduce the influence from the changes of environment temperature on the measured accuracy;

4.No reference gas is needed, and the analyzer wouldn’t be affected by the oxygen concentration of working around atmosphere;

5.It could do one-way or bidirectional communication with the upper computer;

6.The imported sampling pump is built in and the working mode can be set through the software.

Oxygen analyzer technical parameters:

Test principle

zirconium dioxide

Display mode

128×64 matrix dot LCD 

Test range

0 ~ 10/100/1000ppm / 1.00% / 25.00% O2

Resolution

1ppm

Accuracy

0~1000ppm /1.00% / 10.00% / 25.00% ≤±1% FS

 0~100ppm ≤±2% FS

0~10ppm ≤±5%FS

Repeatability

≤±1%

Response time

T90≤30S

Analog output

4~20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm

0~10V.DC(non-isolated output, loaded resistance higher than 10k Ohm)

1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A)

Communication port

RS232 (default) or RS485

Power supply

AC85 ~ 264V 50/60Hz

Temperature of the sample gas

-10 ~ +50

Sample gas flow

400 ~ 600ml/min

Sampling mode

extraction way, ejection way, extraction and ejection way

Sample gas pressure

micro positive pressure, micro negative pressure or normal pressure

Background gas

Nand inactive gaseous mixture

Appearance Size

133mm×268mm×300mm(H×W×D)

Install Hole Cut

135mm×228mm(H×W)

Serving life

4 years(under normal use)

Gas circuit port

NPT 1/8 internal thread

Install mode

frame mount

Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.

Contact Us
  • E-mail: cysi@cysi.wang
  • Tel: +86 371 5519 9322
  • Fax: +86 371 8603 6875
  • Add: No. 820, 8th Floor, 1st Unit, 9th Block, Cuizhu Street, High-Tech Zone, Zhengzhou, Henan, China




Follow Us

Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved   

| Sitemap |       Technical Support: